Optimal Selection of SSSC Based Damping Controller Parameters for Improving Power System Dynamic Stability Using Genetic Algorithm
Abstract: This paper proposes a new genetic-based approach for optimal selection of the Static Synchronous Series Compensator (SSSC) based damping controller parameters in order to shift the closed loop eigenvalues toward the desired stability region. Controller design is formulated as a nonlinear constrained optimization problem. For simultaneous improvement of objective function (system stability) and constraints (limits of controller gains), their combination is used as the fitness function. The work relies on Genetic Algorithms (to capture the near global solution), analysis of mode abservability (to select the effective feedback signal of the damping controller) and the theoretical analysis of a general Single-Machine Infinite-Bus (SMIB) power system, using its modified linearized Phillips-Heffron model installed with SSSC. Simulation results are presented to show the excellent performance of the proposed SSSC controller in damping the critical modes without significantly deteriorating the damping characteristics of other modes


pdf

code : 76

free

download free

 

khani بازدید : 597 نظرات (0)

A hybrid approach in study of UPFC effects on the transient stability of multi machine power systems

Abstract
In this paper, a hybrid method on investigation of UPFC effects on transient stability of multi machine power system has been introduced. Based on the combination of output results of time domain simulation (TDS) and transient energy function (TEF) analysis, study of power system transient stability is converted to the study of transient stability of only one machine, so called critical machine. The effects of UPFC in three basic control mode namely in-phase voltage control (ivc), quadrature voltage control (qvc) and shunt compensation control (sh.c) on the transient stability margin and for various fault clearing times, has been studied. Based on acquired results, it can be seen that in-phase and quadrature voltage control have the most effects on the improvement of transient stability margin. Also, ivc is more robust than other control modes against increase of fault clearing time. The proposed method determines the critical machine based on the swing curves result from TDS, and then provides SM of the critical machine with trivial computation by use of machine speeds and inertia Constants. The method doesn’t need to include of UPFC description equation in to the transient energy function. The proposed method was successfully demonstrated on the 7-machine CIGRE test system



pdf

code : 75

free

download free

تعداد صفحات : 27

اطلاعات کاربری
آمار سایت
  • کل مطالب : 133
  • کل نظرات : 11
  • افراد آنلاین : 1
  • تعداد اعضا : 109
  • آی پی امروز : 13
  • آی پی دیروز : 29
  • بازدید امروز : 182
  • باردید دیروز : 116
  • گوگل امروز : 0
  • گوگل دیروز : 0
  • بازدید هفته : 372
  • بازدید ماه : 1,435
  • بازدید سال : 11,751
  • بازدید کلی : 236,478